Membranes

1 spent element,3 grades out.

The conditions inside our process set each element's rejection and flow. That's how 1 spent seawater element becomes High Flow, High Rejection or Super High Rejection.

Second Life RO regenerated element with its carton and the 3-year prorated limited warranty seal

Typical specifications

8 inch elements, tested to ISO 20466:2024.

GradeSKUPermeate flow, GPD (m³/d)Min. salt rejectionFeed spacerISO 20466 class
High Flow2L-HF8040-T>10,050 (>38)>96.0%28 milC4
High Rejection2L-HR8040-T>7,950 (>30)>98.5%28 milB5
Super High Rejection2L-SHR8040-T>5,283 (>20)>99.3%28 milA5

Test conditions

All 3 grades: 2,000 ppm NaCl, 225 psi (15.5 bar g), 77 °F (25 °C), pH 8, 15% recovery.

Performance is measured after about 30 minutes of operation and normalised back to these conditions. Permeate flow for individual elements may vary ±15%.

Which grade suits which duty

High Flow for brackish duty where flow matters most: municipal wastewater, agriculture, industry, mining, pulp and paper.

High Rejection for the same brackish duties where salt passage matters more than throughput.

Super High Rejection where you need the highest rejection of the 3 grades.

Dimensions
Length40.0 in (1,016 mm)
Permeate tube, inside diameter1.125 in (28.6 mm)
Diameter7.89 in (200 mm)

Ships with a new brine seal, in a sealed polyethylene bag with less than 1.0% sodium metabisulfite solution, in its own carton. Shipped by the pallet, 25 elements.

Morgan Meinecke beside a finished pallet of boxed elements in the plant
Suggested operating conditions
Membrane typePolyamide thin-film composite
Max. operating temperature113 °F (45 °C)
Max. operating pressure600 psig (41 bar)
Max. pressure drop, per element15 psig (1.0 bar)
Max. pressure drop, per vessel (4 or more elements)50 psig (3.5 bar)
pH, continuous operation2 to 11
pH, short-term cleaning (30 min)1 to 13
Max. feed silt density indexSDI 5
Free chlorine tolerance< 0.1 ppm

Oxidation damage isn't covered by the warranty. Remove residual free chlorine in pretreatment before the feed reaches the membrane.

Where they fit, and where they don't

A regenerated element holds 85 to 90% of a new membrane's rejection and flow.

For most secondary duties that's the right call, at 30 to 50% less than a new element, and a lower price every replacement cycle.

For drinking water and first-pass seawater at full spec, buy new, and we'll tell you so.

85 to 90% of a new element's rejection and flow Save 30 to 50% cost

Applications

Where our elements fit.

Water and reuse

Municipal wastewater and reuseBrackish water ROLandfill leachate

Industry

Refining and petrochemicalsOil and gas waterMiningPulp and paper

Farming

Agriculture and irrigationLivestock wastewater

Not for drinking water, or for any food or beverage meant for human consumption.

Documents

Datasheets and warranty.

Every grade has its own datasheet with full specifications, operating limits and handling guidance. Leave your details and download them straight away.

2L-HF8040-T

High Flow, brackish water, 8 inch.

Get the datasheet

2L-HR8040-T

High Rejection, brackish water, 8 inch.

Get the datasheet

2L-SHR8040-T

Super High Rejection, brackish water, 8 inch.

Get the datasheet

Get the datasheets.

Tell us who you are and the download starts here. We use your details to follow up on your enquiry, nothing else. See our privacy notice.

Thanks. Here you go.

The links work for 30 minutes.

3-year prorated limited warranty

Every element ships serial numbered, vacuum-sealed and boxed, with a 3-year prorated limited warranty. The warranty prevails over our general terms and conditions.

Read the full warranty →

Start with Try & Buy

Buy 2 to 8 elements for 1 pressure chamber and run them beside your current elements on the same feed. We agree the water in and the water out in writing first, and both sides measure. If you're not happy, you get your money back. You pay the freight.

First, check your saving →

Morgan Meinecke

Don't trust a regenerated membrane you haven't tested.

Which is exactly why we start with 1 chamber. Put our elements next to yours, on your water, and read the numbers off your own plant.

Talk to us

Tell us what the water does.

The application, the feed water, the flow and the quality you need out. That's enough for us to recommend a grade, quote a price and tell you straight whether regenerated fits the duty, with the cost per m³ against what you run now.

A larger project? We can run a full system projection for your plant. Tick the box and we'll send you our project questionnaire.

+971 7 244 8033

Received.

We reply from Ras Al Khaimah, GMT+4, usually the same working day.

Get the datasheets